Thermo Fisher Scientific

  • Home
  • Thermo Fisher Scientific

Filter by Price

Brand

  • Choice
  • Nalgene
  • Nunc
  • Target2
  • Thermo Fisher Scientific
  • Titan3

Make

  • Thermo Fisher Scientific
  • Thermo Fisher scientific USA
  • Thermofisher Scientific

Pore Size (Å)

  • 0.2 µm
  • 0.25 µm
  • 0.45 µm
  • 0.7 µm
  • 0.8 µm
  • 1.0 µm
  • 1.1 µm
  • 1.2 µm
  • 1.25 µm
  • 3.1 µm
  • 5.0 µm

pH Range

  • 1–13, chloride concentration up to 0.1 mol/L

Temperature Range (°C)

  • Yes, 5-85°C - Column Compartment Thermostatting (Still air and forced air)

Display

  • Touchscreen user interface display compatible

Detector

  • Other Detector Choice: Vanquish Charged Aerosol Detector Vanquish Diode Array Detector Vanquish Fluorescence Detector Vanquish Multiple Wavelength Detector Vanquish Variable Wavelength Detector Refractive Index Detector Mass Spectrometer
  • Other Detector Choice: Vanquish Charged Aerosol Detector Vanquish vWD (UV) Detector Vanquish Fluorescence Detector Vanquish Multiple Wavelength Detector Vanquish Variable Wavelength Detector Refractive Index Detector Mass Spectrometer

Dimension (Length)

  • 70 mm

Flow rate

  • 0–10 mL/min

Max. (Capacity)

  • 1.8 mL

Maximum tube diameter

  • 12.5 mm (outer)

Maximum load capacity

  • 3.6 mL

Dimension (Diameter)

  • 13 mm (Metric)
  • 17 mm (Metric)
  • 25 mm (Metric)
  • 30 mm (Metric)
  • 4 mm (Metric)

Pressure range

  • 115 PSI
  • 150 PSI
  • 210 PSI
  • 700 bar
  • 75 PSI
  • 90 PSI

Material of construction (MOC)

  • Plastic
  • Polypropylene

colour

  • Natural

Disposable

  • Yes

Housing Material

  • Medical Grade, Solvent-Resistant, Virgin Polypropylene
  • Polypropylene (Housing)
  • Solvent Resistent, Low-Extractable Polypropylene

Prefilter

  • No

Material Membrane Dia (mm)

  • Cellulose Acetate
  • Glass Fiber
  • Glass Microfiber
  • Nylon
  • PES
  • Polypropylene
  • PTFE
  • PTFE (Hydrophilic)
  • PTFE (Hydrophobic)
  • PVDF
  • PVDF (Hydrophilic)
  • PVDF (Hydrophobic)
  • Regenerated Cellulose
  • SFCA

Sterility

  • Non-sterile
  • sterile
  • Yes

Bottom Shape

  • Flat Bottom
  • Round

Thread Style

  • External Thread

For Use With (Equipment)

  • Cryobank

Anti-Rotation

  • No

Closure Type

  • Screw Cap (Not Included)

Dnase Free

  • Yes

RNase Free

  • Yes

Vapor LN2 (to -150°C)

  • Yes

Volume

  • 10 to 100 mL (Sample)
  • 2 to 10 mL

Pump options

  • Binary (400 µL) Quaternary (679 µL) Isocratic

Biocompatible

  • No

System design

  • Modular

Solvent monitoring system compatible

  • Yes

Customizable gradient delay volume to simplify method transfer

  • Yes, with method transfer kit

SmartInject technology for maximum injection precision and improved column lifetime

  • Yes

Injection volume range

  • Standard: 0.01-100 µL Optional: 0.01-1000 µL

Sample cooling

  • Yes, 4-40°C Dependent on sampler selected

Sample capacity (standard) Based on standard 12 mm OD vials (= 1.5 mL)

  • 4 racks of 54 vials (= 1.5 mL) each, other rack formats available + capacity of 12 × 22.5 mm OD vials (= 10 mL) in the carousel

Sampler extension available (optional)

  • Yes, with Vanquish Charger

Column compartment pre-heater

  • Active (optional) Passive

Column compartment post-column cooler

  • No